Turbine flow meter threaded connection VCT-AN
Delivery time: 4 weeks
VCT-AN
Thread
Individual request
Is your specific configuration not listed, are you looking for a special solution or do you need large quantities? Our team is looking forward to your individual task.
Please write to us.Functional description
The VCT rotor geometry is further optmized and supported by a high-performance hybrid ball bearing. Those improvements resulting in a wide turndown and excellent repeatability. The turbine speed is detected with no drag to the rotor and converted into a common TTL frequency output. A miniaturized media exposed probe take accurate dynamic readings of process media temperature. VCT defaults and calibration data are stored within an integrated data memory. Combined with the smart flow computer VCA or VCA-T series a plug and play low measuring systems is operating at high accuracy and independent from fluid viscosity.
Product details
Temperature Range
Output signal
Dimensions
Type | Inner Ø | Measurement range | AN thread | SW | Filter | ||||
---|---|---|---|---|---|---|---|---|---|
min. | max. | A | B | C | Masse | ||||
VCT-AN | [mm] | [Lit./Min.] | [Lit./Min.] | [mm] | [mm] | [mm] | [g] | [mm] | [mm] |
0005 | 6,8 | 0,05 | 5 | AN8 | 56 | 35 | 140 | 21 | 10 |
0010 | 6,8 | 0,1 | 10 | AN8 | 56 | 35 | 140 | 21 | 10 |
0020 | 7,9 | 0,2 | 20 | AN8 | 56 | 35 | 140 | 21 | 10 |
0030 | 9,9 | 0,3 | 30 | AN8 | 56 | 35 | 140 | 21 | 10 |
0060 | 12,3 | 0,6 | 60 | AN10 | 69 | 38 | 190 | 21 | 10 |
0100 | 15,5 | 1,0 | 100 | AN12 | 80 | 43 | 280 | 21 | 10 |