Kontakt

Call Back

DDM Shop – Pressure sensors & Flow meters

Oval Gear Meters

oval gear meter 1l-min Ovalradzähler 1l-min-OG1
From 411,40 

Connection: 1/4" BSP F or NPT F

Measurement range: 0,01 ... 1,0l/min at 30cst oil; 0,1 ... 1,0l/min with water

Repeatability: ±0,1%

Output: Impuls NPN; voltage

Pressure Ranges: <10bar, <50bar, <400bar, <700bar

Temperature range: -20 - 80°C, -40 - 100°C, -40 - 150°C

Data sheet: pdf | 253 KB

From 411,40 
Select options
oval gear meter 4l-min Ovalradzähler 4l-min-OG2
From 411,40 

Connection: 1/4" BSP F or NPT F

Measurement range: 0,03 ... 4,0l/min at 30cst oil; 0,15 ... 4,0l/min with water

Repeatability: ±0,1%

Output: Impuls NPN; voltage

Pressure Ranges: <10bar, <50bar, <400bar, <700bar

Temperature range: -20 - 80°C, -40 - 100°C, -40 - 150°C

Data sheet: pdf | 261 KB

From 411,40 
Select options
oval gear meter 10l-min Ovalradzähler 10l-min-OG3
From 1.052,10 

Connection: 1/2" BSP F or NPT F

Measurement range: 0,05 ... 10,0l/min at 30cst oil; 0,5 ... 10,0l/min with water

Repeatability: ±0,1%

Output: Impuls NPN; voltage

Pressure Ranges: <10bar, <50bar, <400bar, <700bar

Temperature range: -20 - 80°C, -40 - 100°C, -40 - 150°C

Data sheet: pdf | 274 KB

From 1.052,10 
Select options
oval gear meter 50l-min Ovalradzähler 50l-min-OG4
From 1.333,50 

Connection: 3/4" BSP F or NPT F

Measurement range: 0,25 ... 50,0l/min at 30cst oil; 2,5 ... 50,0l/min with water

Repeatability: ±0,1%

Output: Impuls NPN; voltage

Pressure Ranges: <10bar, <50bar, <400bar, <700bar

Temperature range: -20 - 80°C, -40 - 100°C, -40 - 150°C

Data sheet: pdf | 240 KB

From 1.333,50 
Select options
oval gear meter 100l-min Ovalradzähler 100l-min-OG5
From 2.971,90 

Connection: 1" BSP F or NPT F, R21.50, G1-11

Measurement range: 0,5 ... 100,0l/min at 30cst oil; 4,0 ... 100,0l/min with water

Repeatability: ±0,1%

Output: Impuls NPN; voltage

Pressure Ranges: <10bar, <50bar, <400bar

Temperature range: -20 - 80°C, -40 - 100°C, -40 - 150°C

Data sheet : pdf | 233 KB

From 2.971,90 
Select options
oval gear meter 200l-min Ovalradzähler 200l-min-OG6
From 4.285,80 

Connection: 1 1/2" BSP F or NPT F

Measurement range: 2 ... 200l/min at 30cst Öl; 10 ... 200l/min with water

Repeatability: ±0,1%

Output: Impuls NPN; voltage

Pressure Ranges: <10bar, <50bar, <400bar,

Temperature range: -20 - 80°C, -40 - 100°C, -40 - 150°C

Data sheet: pdf | 225 KB

From 4.285,80 
Select options
oval gear meter 500l-min Ovalradzähler 500l-min-OG7
Price on Application

Connection: 2" BSP F or NPT F

Measurement ranges: 5 ... 500l/min at 30cst oil; 20 ... 500l/min with water

Wiederholbarkeit: ±0,1%

Output: Impuls NPN; voltage

Pressure Ranges: <50bar

Temperature range: -20 - 80°C, -40 - 100°C, -40 - 150°C

Data sheet: pdf | 220 KB

Price on Application
Select options

Ultrasonic

ultrasonic knife industry Ultraschall-Durchflussmesser Industrie-atrato
From 830,20 

Connection: 3/8” John Guest, 1/2” BSP, 1/2” NPT

Measurement range: 2 ... 500ml/min to 0,1 ... 20l/min

Repeatability: ±0.1% (25 to 100% v.MB); ±0.5% (< 25 v.MB)

Material of wetted parts: PEEK / 316 ; PEEK / Borosilikatglas

Output: Impuls (NPN or PNP); 4 - 20mA; 0 - 10V; 0 -5V; Display

Temperature range: -10 - 60°C, -10 - 110°C

Data sheet: pdf | 1 MB

From 830,20 
Select options
ultrasonic flow meter PFA hose Ultraschall-Durchflussmesser PFA Schlauch-MetraFlow
From 1.512,30 

Connection: 1/8” & 1/4" hose

Measurement ranges: 20 ... 1000 ml/min & 100 ... 5000 ml/min

Repeatability: ±0.1% plus ±0.02% FSD

Material of wetted parts: PFA hose with FDA approval

Output: Impuls (NPN or PNP); 4 - 20mA; 0 - 10V; 0 -5V; Display

Temperature range: -10 - 60°C

Data sheet: pdf | 1,003 KB

From 1.512,30 
Select options
ultrasonic flow meter prozess Ultraschall-Durchflussmesser Prozess Atrato
From 951,40 

Connection: ¼” BSP

Measurement range: 2 ... 500ml/min to 0,1 ... 15l/min

Repeatability: ±0.1% +0.005% FSD

Material of wetted parts: 316 and PEEK

Output: Impuls (NPN or PNP);

Data sheet: pdf | 643 KB

Manuel: pdf | 736 KB

From 951,40 
Select options

Pelton wheel flowmeters

Flügelradzähler Beverage Mini mit NSF169-Zertifizierung und herforagendem Preis - Leistungsverhältnis | Beverage Mini impeller meter with NSF169 certification and outstanding price-performance ratio
From 33,30 

Hose connection Ø: 3/8“

Measurement range: 0,6 - 10 l/min

Repeatability: 0,1%

Material of wetted parts: PVDF including NSF

Output: Impuls (NPN or PNP)

Temperature range: -25 to 125°C

Data sheet: pdf | 129 KB

From 33,30 
Select options
pelton wheel flow meter Flügelradzähler-800-Serie
From 67,30 

Hose connection Ø: 8 & 12mm

Measurement range: 0,05... 0,5 l/min to 0,50 ... 15,0 l/min

Repeatability: 0,1%

Material of wetted parts: PVDF including NSF, customer-specific

Output: Impuls (NPN or PNP)

Temperature range: -25 ... 60°C or -25 ... 125°C

Data sheet: pdf | 244 KB

From 67,30 
Select options
pelton wheel flow meter Flügelradzähler-900-Serie
From 308,60 

Connection: 1/4" BSPF, 1/4" NPTF

Measurement range: 0,05... 0,5 l/min to 0,50 ... 15,0 l/min

Repeatability: 0,1%

Material of wetted parts: PVDF or stainless steel

Output: Impuls (NPN or PNP)

Temperature range: -25 ... 60°C or -25 ... 125°C

Data sheet: pdf | 410 KB

From 308,60 
Select options
pelton wheel flow meter Flügelradzähler-1000 Serie
From 380,80 

Connection: 1/2" BSPF

Measurement range: 0,05... 0,5 l/min to 2,0 ... 30,0 l/min

Repeatability: 0,1%

Material of wetted partsin contact with media: PVDF or stainless steel

Output: Impuls (NPN or PNP)

Temperature range: -25 ... 60°C or -25 ... 125°C

Data sheet: pdf | 270 KB

From 380,80 
Select options
optical detection turbine flow meters
From 177,60 

Connection: 8mm & 13mm hose; ¼“ up to 1“ BSP

Measurement range: 0,5 l/min to 160,0 l/min

Repeatability: 0,1%

Material of wetted parts : PVDF, PVC, Brass or Stainless Steel

Output: Impuls

Temperature range : -15 up to 125°C

Data sheet FT2 hall effect: pdf | 245 KB

From 177,60 
Select options
optical detection turbine flow meters
From 177,60 

Connection: 8mm & 13mm hose; ¼“ up to 1“ BSP

Measurement range: 0,02 l/min up to 160,0 l/min

Repeatability: 0,1%

Material of wetted parts : PVDF, PVC, Brass or Stainless Steel

Output: Impuls

Temperature Range : -10 to 80°C

Data sheet FT2 optical: pdf | 238 KB

From 177,60 
Select options

Instruments & Displays

Signalkonvertor für standard Durchflussmesser Signalausgang: Spnnung, Strom & Frequenz | Signal converter for standard flow meter signal output: voltage, current & frequency
From 328,20 

Linearisation: Calibration points of the flow meter can be stored

Signal input: Pulse or Reed switch

Response time: from 100ms

Flow alarm outputs: programmable high and low alarms

Operating temperature range: 0 - 65°C

Protection class: IP64

Data sheet Pulsit Link: pdf | 676 KB

From 328,20 
Select options
Anzeige Pulsit Solo | Display Pulsit Solo
From 191,00 

LCD display: current flow rate & total flow rate

Possible units: Gal - cc - kg - gms - Ltr & sec - min - Hr

Power supply: 5 to 24Vdc or AA battery

Protection class: IP64

Data sheet Pulsit solo: pdf | 497 KB

From 191,00 
Select options

Flow Computer - small & intelligent

Aufbau Diagnose Interface - Hardware und Software | Structure of the diagnostic interface - hardware and software
Price on Application
Price on Application
Select options
flow computer VCA
Price on Application

Input signal: max. 2,5 kHz (TTL)

Accuracy: ± 0,1%

Operating temperature range: -40 to +125°C

Output: 0 to 10V

Datasheet : pdf | 267 KB

Price on Application
Select options
flow-computer-vca-can
Price on Application

Input signals: 2.5 kHz TTL max.

Accuracy: ± 0,1 %

Operating temperature range: −40 °C to+125 °C

Output: CAN-BUS 2.0B high speed (ISO 11989-2:2016)

Data sheet: pdf | 237 KB

Price on Application
Select options
flow computer VCA
Price on Application

Input signal: max. 2,5 kHz (TTL)

Accuracy: ± 0,1%

Operating temperature range: -40 to +110°C

Output: 0 to 20mA or 4 to 20mA

Datasheet : pdf | 267 KB

Price on Application
Select options
flow computer with temperature output Flow Computer mit Temperaturausgang-VCA-T
Price on Application

Input signal: max. 2,5 kHz (TTL)

Accuracy: ± 0,1%

Operating temperature range: -40 to +110°C

Output: 0 to 20mA or 4 to 20mA

Data sheet : pdf | 257 KB

Price on Application
Select options
flow computer with temperature output Flow Computer mit Temperaturausgang-VCA-T
Price on Application

Input signal: max. 2,5 kHz (TTL)

Accuracy: ± 0,1%

Operating temperature range: -40 to +125°C

Output: 0 to 10V

Data sheet : pdf | 257 KB

Price on Application
Select options

Smart-Pickoff - TTL output / open collector

flow turbine pickoff Messaufnehmer-Smart-Pickoff ASP
Price on Application

Input Frequency: 0.5 to 2,000 Hz

thread connector: 11/16"-24UNEF; 5/8"-18UNF others on request

Temperature probe : thermocouple Type T

Datasheet_Smart-Pickoff_EN: pdf | 249 KB

Price on Application
Select options

Turbine flow meter

turbine flow meter threaded Connection Messturbine Gewindeanschluss-VCT-AN
Price on Application

Thread: AN8; AN10; AN12

Measurement ranges: 0,1 to 100l/m

Repeatability: ± 0,025 % of reading

Temperature probe media exposed: Type T thermocouple

Datasheet : pdf | 314 KB

Price on Application
Select options
Hose barbed connection Messturbinen Schlauchanschluss-VCT
Price on Application

Hose connection Ø: 9,8 to 32mm

Measurement range: 0,1 to 350l/min

Repeatability: ± 0,025 % of reading

Temperature probe media exposed: Type T thermocouple

Datasheet : pdf | 314 KB

Price on Application
Select options

Pressure sensors

customized pressure sensor Kundenspezifischer Drucksensor-Sensor Solution

Ø: Customer specificity

Measurement range: 0...100mbar to (-1) 0...150 bar

Output:  Voltage, current, CAN protocols, IO-Link

Comp. Temperature Range: 0..50°C to -40...180°C

Pressure connection: Customised

pressure sensor Drucksensor-PV10
Price on Application

Ø: 10 mm

Measurement range: 5 bar to 250 bar (Any ranges in between)

Output: 0,5 to 4,5 V

Comp. Temperature Range: -40°C to +180°C

Pressure connection: M5x0,8

Datasheet : pdf | 167 KB

Price on Application
Select options
pressure sensor Drucksensor-PV15
Price on Application

Ø: 16 mm

Gauge pressure: (-1) 0...2,5bar to (-1) 0...150 bar (Any ranges in between)

Absolute pressure: 0...2,5bar to 0...150 bar (Any ranges in between)

Output: 0,5 to 4,5 V

Comp. Temperature Range: -40°C to +125°C

Pressure connection: M6x1; M8x1

Datasheet: pdf | 327 KB

Price on Application
Select options
Mini Drucksensor PV15B Temperaturkompensiert -40 bis 150°C | Mini pressure sensor PV15B Temperature compensated -40 to 150°C
Price on Application

Ø: 16 mm

Pressure Ranges (FRO):: 0 to 200 bar rel. (others on request)

Overpressure: 300 bar

Burst pressure: 400 bar

Output Signal (3-wire): 0.5 to 4.5 V

Response Time: < 0,5 ms

Operating Temperature Range: −40 °C to +150 °C

Datasheet: pdf | 375 KB

Price on Application
Select options
pressure sensor Drucksensor-PV15H
Price on Application

Ø: 16 mm

Gauge pressure: (-1) 0...2,5bar to (-1) 0...150 bar (Any ranges in between)

Absolute pressure: 0...2,5bar to 0...150 bar (Any ranges in between)

Output: 0,5 to 4,5 V

Comp. Temperature Range: -40°C to +150°C

Pressure connection: M6x1; M8x1 (Others on request)

Datasheet : pdf | 374 KB

Price on Application
Select options
pressure sensor Drucksensor-PV22
Price on Application

Ø: 22 mm

Gauge pressure: 100 mbar to 150 bar (Any ranges in between; Bidirectional)

Absolute pressure: 2 bar to 150 bar (Any ranges in between)

Output: 0 to 5 V or 1 to 6 V

Comp. Temperature Range: -40°C to +125°C

Pressure connection: M10x1; M14x1,5; 7/16 - 20UNF; G1/4 male; Rectus 21

Datasheet : pdf | 271 KB

Price on Application
Select options
pressure sensor Drucksensor-PV22 TEDS
Price on Application

Ø: 22 mm

Gauge pressure: 100 mbar to 150 bar (Any ranges in between ;Bidirectionall)

Absolute pressure: 1 bar to 150 bar (Any ranges in between)

Output: 0 to 5 V or 1 bis 6 V

Comp. Temperature Range: -40°C to +125°C

Pressure connection: M10x1; M14x1,5; 7/16 - 20UNF; G1/4 male; Rectus 21

Datasheet : pdf | 252 KB

Price on Application
Select options
Drucksensor PV22 Druckanschluss M14x1.5 mit 60° Innenkunus elektrischer Anschluss MIL-C26482 | Pressure sensor PV22 Pressure connection M14x1.5 with 60° internal cone Electrical connection MIL-C26482
Price on Application

Ø: 22 mm

Gauge pressure: 0 to 4 bar (other pressure ranges on request)

Absolute pressure: 0 to 5 bar (other pressure ranges on request)

Output: 0 to 5 V or 1 to 6 V (others on request)

Comp. Temperature Range: -40°C to +125°C

Pressure connections: M10x1; M14x1,5; 7/16 - 20UNF; G1/4

Datasheet : pdf | 228 KB

Price on Application
Select options
pressure sensor Drucksensor-PV22H
Price on Application

Ø: 22 mm

Gauge pressure: 100 mbar to 150 bar (Any ranges in between;Bidirectional)

Absolute pressure: 250 mbar to 150 bar (Any ranges in between)

Output: 0,5 to 4,5 V

Comp. Temperature Range: -40°C to +150°C

Pressure connection: M10x1; M14x1,5; 7/16-20UNF

Datasheet : pdf | 280 KB

Price on Application
Select options
pressure sensor Drucksensor-PV-25H
From 475,00 

Ø: 25mm

Gauge pressure: 100 mbar to 150 bar (Any ranges in between;Bidirectional)

Absolute pressure: 250 mbar to 150 bar (Any ranges in between)

Output: 0 to 5 V or 0 to 10 V

Comp. Temperature Range: -20°C to +80°C

Pressure connection: G1/4" female, G1/4" male to DIN 3852 T11 seal incl.

Datasheet : pdf | 293 KB

From 475,00 
Select options
pressure sensor Druckmessumformer-PV25L
From 450,00 

Ø: 25 mm

Gauge pressure: 100 mbar bis 150 bar (beliebige Zwischenbereiche; Bidirectional)

Absolute pressure: 250 mbar bis 150 bar (beliebige Zwischenbereiche)

Output: 0 bis 5V oder 0 bis 10V

Comp. Temperature Range: 0°C bis +50°C

Pressure connections: G1/4“ female; G1/4“ male to DIN 3852 T11 seals incl.

Datasheet: pdf | 293 KB

From 450,00 
Select options
differential pressure sensor Differenzdruck Sensor-PV2722
Price on Application

Ø: 27 mm

Measurement range: 100 mbar bis 3,5 bar (Any ranges in between; Bidirectional)

Output: 0 to 5 V or 1 to 6 V

Comp. Temperature Range: 0 to +50°C, -20 to 80°C or -40 to 125°C

Pressure connection: M10x1

Datasheet : pdf | 368 KB

Price on Application
Select options
Drucktransmitter PX25L von DDM Sensors mit kleinem Gesamtfehler | Pressure transmitter PX25L from DDM Sensors with small total error
From 475,00 

Ø: 25 mm

Gauge pressure: 100 mbar to 150 bar (Any ranges in between; Bidirectional)

Absolute pressure : 250 mbar to 150 bar (Any ranges in between)

Output: 4 to 20 mA

Comp. Temperature Range: -20°C to +80°C

Pressure connections: G1/4" female , G1/4" male to DIN 3852 T11

Datasheet : pdf | 283 KB

From 475,00 
Select options
Drucktransmitter PX25L von DDM Sensors mit kleinem Gesamtfehler | Pressure transmitter PX25L from DDM Sensors with small total error
From 450,00 

Ø: 25 mm

Gauge pressure: 100 mbar to150 bar (Any ranges in between; Bidirectional)

Absolute pressure: 250 mbar to 150 bar (Any ranges in between)

Output: 4 to 20 mA (two-wire)

Comp. Temperature Range: 0°C to +50°C

Pressure connection: G1/4“ female; G1/4“ male to DIN 3852 T11 seal incl.

Datasheet : pdf | 283 KB

From 450,00 
Select options

Data protection settings
We need your consent!

We use cookies and external services on our website with your consent in order to personalize content and advertising, offer functions and analyze your access to our website. We share this information with our partners, who may merge it with other data they have previously collected (category: external media). In order to be able to offer technically necessary functions securely, certain cookies are always active (category: Essential).

By selecting and clicking on Accept, you consent to the data processing described (TDDDG and GDPR). You can revoke your consent at any time with effect for the future via the data protection page.

Further information on the processing of your personal data can be found under Show details and in our data protection information.

Show details

Cookies details

  • Essential:
    • Technically necessary cookies

      Provider
      DDM GmbH & Co. KG

      Name (purpose) - Duration of processing (storage period)

      • Pll_language (language setting) - Storage period: 12 months
      • Com4cookies_options (consent management) - Storage period: 1 month
      • __stripe_mid (fraud prevention) - Storage duration: end of session 12 months
      • __stripe_sid (fraud prevention) - Storage duration: end of session
      • Woocommerce_items_in_cart (shopping cart storage) - Storage duration: End of session
      • Wp_woocommerce_session_* (user actions) - storage duration: 2 days
      • Woocommerce_cart_hash (shopping cart storage) - Storage duration: End of session
      • Wordpress_logged_in_* (maintaining the login) - Storage duration: End of session
      • Wfwaf_authcookie_* (detection of the login) - storage duration: 12 hours
      • Wordpress_sec_* (security settings) - Storage duration: 15 days

      Processing location
      Germany

      Legal basis
      The processing of personal data is based on a legal obligation pursuant to Art. 6 para. 1 sentence 1 lit. c GDPR; the exception pursuant to Section 25 para. 2 no. 2 TDDDG applies to the storage of information in your terminal equipment.

      Further information
      Further information on the processing of data and individual storage periods can be found in our data protection information under VI Use of cookies.

  • External media:
    • Service: Google Maps

      Provider
      Google Ireland Limited

      Purpose of use
      Display of a map

      Processing location
      European Union, USA

      Legal basis
      The processing of personal data is based on your consent in accordance with Art. 6 para. 1 sentence 1 lit. a GDPR. The storage of information in your terminal equipment takes place on the basis of Section 25 (1) sentence 1 TDDDG.

      Duration of processing (storage period)
      The storage period is determined by Google.

      Further information
      Data collected via Google Maps may be forwarded to third parties and to the USA. The parent company Google LLC. is certified in accordance with the EU-US Data Privacy Framework and has undertaken to comply with European data protection standards. Further information on the processing of data can be found in our data protection information under I. 4. Data transfer to a third country or an international organization and XII. Google Maps.

    • Service: Google Tag Manager and Google Analytics

      Provider
      Google Ireland Limited

      Purpose of use
      Management of website tags (Google Tag Manager), analysis of the user behavior of our website visitors (Google Analytics)

      Processing location
      European Union, USA

      Legal basis
      The processing of personal data is based on your consent in accordance with Art. 6 para. 1 sentence 1 lit. a GDPR. The storage of information in your terminal equipment takes place on the basis of Section 25 (1) sentence 1 TDDDG.

      Duration of processing (storage period)
      The storage period is determined by Google. Data stored by Google at user and event level is anonymized or deleted after 14 months.

      Further information
      Data collected via Google services can be forwarded to third parties and to the third country USA. The parent company Google LLC. is certified in accordance with the EU-US Data Privacy Framework and has undertaken to comply with European data protection standards. Further information on the processing of data can be found in our data protection information under I. 4. Data transfer to a third country or an international organization and XV. Google Tag Manager and XVI. Google Analytics.