0 to 50°C

Ø: 25 mm

Gauge pressure: 100 mbar bis 150 bar (beliebige Zwischenbereiche; Bidirectional)

Absolute pressure: 250 mbar bis 150 bar (beliebige Zwischenbereiche)

Output: 0 bis 5V oder 0 bis 10V

Comp. Temperature Range: 0°C bis +50°C

Pressure connections: G1/4“ female; G1/4“ male to DIN 3852 T11 seals incl.

Datasheet

pdf | 293 KB

Ø: 25 mm

Gauge pressure: 100 mbar to150 bar (Any ranges in between; Bidirectional)

Absolute pressure: 250 mbar to 150 bar (Any ranges in between)

Output: 4 to 20 mA (two-wire)

Comp. Temperature Range: 0°C to +50°C

Pressure connection: G1/4“ female; G1/4“ male to DIN 3852 T11 seal incl.

Datasheet

pdf | 283 KB

Ø: 27 mm

Measurement range: 100 mbar bis 3,5 bar (Any ranges in between; Bidirectional)

Output: 0 to 5 V or 1 to 6 V

Comp. Temperature Range: 0 to +50°C, -20 to 80°C or -40 to 125°C

Pressure connection: M10x1

Datasheet

pdf | 368 KB

-20 to 80°C

Ø: 25mm

Gauge pressure: 100 mbar to 150 bar (Any ranges in between;Bidirectional)

Absolute pressure: 250 mbar to 150 bar (Any ranges in between)

Output: 0 to 5 V or 0 to 10 V

Comp. Temperature Range: -20°C to +80°C

Pressure connection: G1/4" female, G1/4" male to DIN 3852 T11 seal incl.

Datasheet

pdf | 293 KB

Ø: 25 mm

Gauge pressure: 100 mbar to 150 bar (Any ranges in between; Bidirectional)

Absolute pressure : 250 mbar to 150 bar (Any ranges in between)

Output: 4 to 20 mA

Comp. Temperature Range: -20°C to +80°C

Pressure connections: G1/4" female , G1/4" male to DIN 3852 T11

Datasheet

pdf | 283 KB

Ø: 27 mm

Measurement range: 100 mbar bis 3,5 bar (Any ranges in between; Bidirectional)

Output: 0 to 5 V or 1 to 6 V

Comp. Temperature Range: 0 to +50°C, -20 to 80°C or -40 to 125°C

Pressure connection: M10x1

Datasheet

pdf | 368 KB

-40 to 125°C

Ø: 22 mm

Gauge pressure: 0 to 4 bar (other pressure ranges on request)

Absolute pressure: 0 to 5 bar (other pressure ranges on request)

Output: 0 to 5 V or 1 to 6 V (others on request)

Comp. Temperature Range: -40°C to +125°C

Pressure connections: M10x1; M14x1,5; 7/16 - 20UNF; G1/4

Datasheet

pdf | 228 KB

Ø: 16 mm

Gauge pressure: (-1) 0...2,5bar to (-1) 0...150 bar (Any ranges in between)

Absolute pressure: 0...2,5bar to 0...150 bar (Any ranges in between)

Output: 0,5 to 4,5 V

Comp. Temperature Range: -40°C to +125°C

Pressure connection: M6x1; M8x1

Datasheet

pdf | 327 KB

Ø: 22 mm

Gauge pressure: 100 mbar to 150 bar (Any ranges in between ;Bidirectionall)

Absolute pressure: 1 bar to 150 bar (Any ranges in between)

Output: 0 to 5 V or 1 bis 6 V

Comp. Temperature Range: -40°C to +125°C

Pressure connection: M10x1; M14x1,5; 7/16 - 20UNF; G1/4 male; Rectus 21

Datasheet

pdf | 252 KB

Ø: 22 mm

Gauge pressure: 100 mbar to 150 bar (Any ranges in between; Bidirectional)

Absolute pressure: 2 bar to 150 bar (Any ranges in between)

Output: 0 to 5 V or 1 to 6 V

Comp. Temperature Range: -40°C to +125°C

Pressure connection: M10x1; M14x1,5; 7/16 - 20UNF; G1/4 male; Rectus 21

Datasheet

pdf | 271 KB

Ø: 27 mm

Measurement range: 100 mbar bis 3,5 bar (Any ranges in between; Bidirectional)

Output: 0 to 5 V or 1 to 6 V

Comp. Temperature Range: 0 to +50°C, -20 to 80°C or -40 to 125°C

Pressure connection: M10x1

Datasheet

pdf | 368 KB

-40 to 150°C

Pressure Ranges (FRO):: 0 to 200 bar rel. (others on request)

Overpressure: 300 bar

Burst pressure: 400 bar

Output Signal (3-wire): 0.5 to 4.5 V

Load Impedance: > 5 kOhm

Measurement Performance: Total Error Band within Operating Temperature Range (includes non-linearity, hysteresis, repeatability, zero and span settings, thermal shift on zero and span) ≤ 1 % FRO

Stability: ≤ 0.2 % FRO per year (typically)

Response Time: < 0,5 ms

Operating Temperature Range: −40 °C to +150 °C

Datasheet

pdf | 375 KB

Ø: 16 mm

Gauge pressure: (-1) 0...2,5bar to (-1) 0...150 bar (Any ranges in between)

Absolute pressure: 0...2,5bar to 0...150 bar (Any ranges in between)

Output: 0,5 to 4,5 V

Comp. Temperature Range: -40°C to +150°C

Pressure connection: M6x1; M8x1 (Others on request)

Datasheet

pdf | 374 KB

Ø: 22 mm

Gauge pressure: 100 mbar to 150 bar (Any ranges in between;Bidirectional)

Absolute pressure: 250 mbar to 150 bar (Any ranges in between)

Output: 0,5 to 4,5 V

Comp. Temperature Range: -40°C to +150°C

Pressure connection: M10x1; M14x1,5; 7/16-20UNF

Datasheet

pdf | 280 KB

-40 to 180°C

Ø: 10 mm

Measurement range: 5 bar to 250 bar (Any ranges in between)

Output: 0,5 to 4,5 V

Comp. Temperature Range: -40°C to +180°C

Pressure connection: M5x0,8

Datasheet

pdf | 167 KB

Temperature range according to the customer requirements

Ø: Customer specificity

Measurement range: 0...100mbar to (-1) 0...150 bar

Output:  Voltage, current, CAN protocols, IO-Link

Comp. Temperature Range: 0..50°C to -40...180°C

Pressure connection: Customised

Notice.